Cables for Flomid FX & Flomat FX series Instructions Manual R-MI-CAFLFX Rev.: 0 English version instrumentación para fluidos
1. INTRODUCTION When an installation requires that the electromagnetic sensor is separated from the control unit, the union between these two elements
3
3. INSTALLATION OF THE INTERCONNECTION CABLE The following points must be taken into account: • The cable should be installed in a conduit or shoul
The Pair 1 cables are connected to terminals 1, 2 & 3 for the coil excitation. The Pair 2 cables, for the electrode inputs, are connected to term
Connection to a XT5 converter The Pair 1 cables are connected to terminals Exc B, Exc R & COM for the coil excitation. The Pair 2 cables for elect
4. CABLE SPECIFICATIONS Model: CERVITRONIC PAR-POS Code 04754502 Construction Conductor: Annealed electrolytic copper, tinned As Norm: UNE 21064 Iso